BLIND SPOT MONITORING (BSM) OFF INDICATOR LIGHT ILLUMINATES CONTINUOUSLY [BLIND SPOT MONITORING (BSM) SYSTEM]
id1503a3021100
Item
|
BLIND SPOT MONITORING (BSM) OFF INDICATOR LIGHT ILLUMINATES CONTINUOUSLY
|
Description
|
• The blind spot monitoring (BSM) OFF indicator light illuminates for 3 s or more without the blind spot monitoring (BSM) switch turning off after the ignition switch is turned to the ON position.
|
Possible Causes
|
• Blind spot monitoring (BSM) control module malfunction
• Connectivity master unit (CMU) malfunction
• Instrument cluster malfunction
|
Diagnostic Procedure
Step |
Inspection |
Result |
Action |
---|---|---|---|
1
|
INSPECT IF MALFUNCTION IS IN BLIND SPOT MONITORING (BSM) SWITCH OR INSTRUMENT CLUSTER
• Monitor the blind spot monitoring (BSM) control module (RH) PID BSM_OFF_IL using the M-MDS.
• Turn the blind spot monitoring (BSM) switch on and off.
• Does the PID BSM_OFF_IL monitoring value turn on and off according to the blind spot monitoring (BSM) switch operation?
|
Yes
|
Go to Step 3.
|
No
|
Go to the next step.
|
||
2
|
INSPECT CONNECTIVITY MASTER UNIT (CMU)
• Retrieve DTCs from connectivity master unit (CMU) using the M-MDS.
• Are any DTCs displayed?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
Go to the next step.
|
||
3
|
INSPECT IF MALFUNCTION IS IN INSTRUMENT CLUSTER OR BLIND SPOT MONITORING (BSM) CONTROL MODULE
• Turn on the blind spot monitoring (BSM) OFF indicator light using the M-MDS instrument cluster active command modes WL+IL.
• Does the blind spot monitoring (BSM) OFF indicator light illuminate according to the active command modes?
|
Yes
|
Replace the blind spot monitoring (BSM) control module.
|
No
|
Replace the instrument cluster.
|