DTC U2132:00 [GATEWAY UNIT (GWU) (TYPE-B)]


id0902zc791900


Outline

System malfunction location

Communication error with 360°view monitor control module

Detection condition
•  The gateway unit (GWU) cannot receive CAN signal from the 360°view monitor control module for 5 s or more.
Fail-safe
Not applicable
Possible cause
•  Malfunction in CAN communication line between gateway unit (GWU) and 360°view monitor control module
•  360°view monitor control module malfunction
•  Gateway unit (GWU) malfunction
System wiring diagram
Not applicable
Connector diagram
Not applicable


Diagnostic Procedure

•  Perform an inspection in accordance with the multiplex communication system diagnostic procedure. (See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [TYPE-B (L.H.D.)].) (See CONTROLLER AREA NETWORK (CAN) MALFUNCTION DIAGNOSIS FLOW [TYPE-B (R.H.D.)].)