PURGE SOLENOID VALVE [SKYACTIV-G 2.5T]


id0116q4112300


Purpose, Function

•  The purge solenoid valve introduces evaporative gas absorbed by the charcoal canister to the intake manifold.
•  The purge solenoid valve opens/closes the valve according to the control signal from the PCM.

Construction

•  The purge solenoid valve is located near the catch tank.
ac9uun00002829
•  The purge solenoid valve consists of a coil, spring, and plunger.
amxuun00001521

Operation

•  The coil is energized and the plunger is operated to open/close the purge solenoid valve according to the control signal from the PCM.
amxuun00001522
•  When the purge solenoid valve is open, evaporative gas flows from the charcoal canister to the intake manifold side.

Purge solenoid valve open/closed view

amxuun00001523
•  For evaporative purge control details, refer to the [CONTROL SYSTEM]. (See PURGE SOLENOID VALVE [SKYACTIV-G 2.5T].)

Fail-safe

•  Not applicable