FUEL PUMP UNIT INSPECTION [MZI-3.7]
id0114d2801100
Continuity Inspection
1. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZI-3.7].)
2. To remove the service hole cover, remove the following parts:
3. Disconnect the fuel pump unit connector.
4. Inspect for continuity between fuel pump unit connector terminals B and D.
ac9wzw00002155
|