DTC C1329, C1330, C1331, C1332, C1333, C1334, C1335, C1336, C1527, C1528, C1530, C1531 [DSC/RSC]
id0402b3811600
DTC
|
C1329
C1330
C1331
C1332
C1333
C1334
C1335
C1336
C1527
C1528
C1530
C1531
|
RF outlet solenoid valve coil system
LR outlet solenoid valve coil system
RR outlet solenoid valve coil system
LF outlet solenoid valve coil system
LR inlet solenoid valve coil system
LF inlet solenoid valve coil system
RF inlet solenoid valve coil system
RR inlet solenoid valve coil system
RH traction control solenoid valve coil system
LH traction control solenoid valve coil system
RH stability control solenoid valve coil system
LH stability control solenoid valve coil system
|
|
DETECTION CONDITION
|
• Temperature of a solenoid valve coil exceeds specification.
|
||
POSSIBLE CAUSE
|
• This does not indicate a malfunction since constant control over extended period of time is inhibited to protect the RSC solenoid valve inside the DSC/RSC HU
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
VERIFY DTC TROUBLESHOOTING COMPLETED
• Clear the DTC from the memory.
(See ON-BOARD DIAGNOSIS [DSC/RSC].)
• Are the same DTCs present?
|
Yes
|
Replace the DSC/RSC HU/CM, then go to the next step.
|
No
|
Go to the next step.
|
||
2
|
VERIFY AFTER REPAIR PROCEDURE
• Are any other DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
(See ON-BOARD DIAGNOSIS [DSC/RSC].)
|
No
|
DTC troubleshooting completed.
|