DTC B2937 [POWER LIFTGATE (PLG) SYSTEM]
id0902e9381100
DTC B2937 |
PLG motor circuit malfunction |
---|---|
DETECTION CONDITION
|
PLG motor current is excessively low (less than 1 A)
|
POSSIBLE CAUSE
|
• Open circuit in wiring harness between PLG control module terminal 1E and PLG motor terminal A (PLG drive unit)
• Open circuit in wiring harness between PLG control module terminal 1F and PLG motor terminal B (PLG drive unit)
• PLG motor malfunction
• PLG control module malfunction
|
![]() |
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT WIRING HARNESS BETWEEN PLG CONTROL MODULE AND PLG DRIVE UNIT
• Disconnect the PLG control module connector.
• Disconnect the PLG drive unit connector.
• Inspect the wiring harness between PLG control module terminals 1E and 1F, and PLG drive unit terminals A and B for an open circuit.
• Is the wiring harness normal?
|
Yes
|
Replace the PLG drive unit.
Go to the next step.
|
No
|
Repair or replace the wiring harness.
Go to the next step.
|
||
2
|
VERIFY CORRECTION COMPLETED
• Reconnect the disconnected connector.
• Clear the DTC.
• Operate the PLG system.
• Is DTC B2937 stored?
|
Yes
|
Replace the PLG control module.
|
No
|
DTC troubleshooting completed.
|