DTC B2937 [POWER LIFTGATE (PLG) SYSTEM]


id0902e9381100

DTC B2937

PLG motor circuit malfunction

DETECTION CONDITION
PLG motor current is excessively low (less than 1 A)
POSSIBLE CAUSE
•  Open circuit in wiring harness between PLG control module terminal 1E and PLG motor terminal A (PLG drive unit)
•  Open circuit in wiring harness between PLG control module terminal 1F and PLG motor terminal B (PLG drive unit)
•  PLG motor malfunction
•  PLG control module malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1
INSPECT WIRING HARNESS BETWEEN PLG CONTROL MODULE AND PLG DRIVE UNIT
•  Disconnect the PLG control module connector.
•  Disconnect the PLG drive unit connector.
•  Inspect the wiring harness between PLG control module terminals 1E and 1F, and PLG drive unit terminals A and B for an open circuit.
•  Is the wiring harness normal?
Yes
Replace the PLG drive unit.
Go to the next step.
No
Repair or replace the wiring harness.
Go to the next step.
2
VERIFY CORRECTION COMPLETED
•  Reconnect the disconnected connector.
•  Clear the DTC.
•  Operate the PLG system.
•  Is DTC B2937 stored?
Yes
Replace the PLG control module.
No
DTC troubleshooting completed.