NO.6 INSUFFICIENT AIR (OR NO AIR) BLOWN REAR VENTS
id070300802000
6
|
Insufficient air (or no air) from rear vents
|
DESCRIPTION
|
• Problem with each rear vent and/or duct
• Rear airflow mode does not change when front and/or rear climate control unit mode switches.
|
POSSIBLE CAUSE
|
• Rear vent mode malfunction
• Rear heat mode malfunction
• Rear airflow mode actuator malfunction
• Open, short circuit in wiring or poor connection between front and rear climate control unit
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN VENT MODE
• Does air blow out when in the rear vent mode?
|
Yes
|
Go to the Step 6.
|
No
|
Go to the next step.
|
||
2
|
VERIFY THAT REAR HEATER CONTROL USING FRONT CLIMATE CONTROL UNIT
• Turn the rear heater to ON and OFF using the front A/C control panel.
• Is it possible that the rear heater turns ON and OFF using the front climate control unit?
|
Yes
|
Go to Step 4.
|
No
|
Go to the next step.
|
||
3
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (OPEN, SHORT OR POOR CONNECTION OF TERMINALS BETWEEN FRONT AND REAR CLIMATE CONTROL UNIT) OR ELSEWHERE
• Inspect for open, short or poor connection of terminals between front and rear climate control unit.
• Is there any open, short or poor connection of terminals?
|
Yes
|
Repair or replace malfunctioning part, then go to Step 10.
|
No
|
Go to the next step.
|
||
4
|
INSPECT VENT
• Is the vent clogged?
|
Yes
|
Remove obstruction, then go to Step 10.
|
No
|
Go to the next step.
|
||
5
|
VERIFY THAT REAR A/C DUCT IS INSTALLED
• Is the rear A/C duct properly installed?
|
Yes
|
Inspect the duct for clogging, deformation and air leakage, then go to Step 10.
|
No
|
Install the duct securely in the proper position, then go to Step 10.
|
||
6
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN REAR HEAT MODE
• Does air blow out when in the rear heat mode?
|
Yes
|
Go to the next step.
|
No
|
Inspect the rear vent for clogging, then go to Step 10.
|
||
7
|
INSPECT REAR VENT
• Is the rear vent clogged?
|
Yes
|
Remove obstruction, then go to Step 10.
|
No
|
Go to the next step.
|
||
8
|
INSPECT REAR AIRFLOW MODE ACTUATOR
• Inspect the rear airflow mode actuator.
• Is the rear airflow mode actuator normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the rear airflow mode actuator, then go to Step 10.
|
||
9
|
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (OPEN, SHORT OR POOR CONNECTION OF TERMINALS BETWEEN FRONT CLIMATE CONTROL UNIT AND REAR AIRFLOW MODE ACTUATOR) OR ELSEWHERE
• Inspect for open, short or poor connection of terminals between front climate control unit and rear airflow mode actuator.
• Is there any open, short or poor connection of terminals?
|
Yes
|
Repair or replace malfunctioning part, then go to next step.
|
No
|
Replace the front climate control unit, go to the next step.
|
||
10
|
VERIFY REPAIR
• Does air blow from the rear A/C vent mode?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.
|