DTC B2477 [INSTRUMENT CLUSTER]


id0902e8840500

Description

Instrument cluster configuration error

Detection condition
•  Instrument cluster configuration has not been correctly performed.
Possible cause
•  Instrument cluster configuration error
•  Instrument cluster malfunction

Diagnostic procedure

Step

Inspection

Action

1
PERFORM INSTRUMENT CLUSTER CONFIGURATION
•  Perform the instrument cluster configuration using the M-MDS.
•  Clear the DTC for the instrument cluster using the M-MDS.
•  Retrieve the instrument cluster DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Perform the instrument cluster configuration again, then go to the next step.
No
Go to Step 3.
2
VERIFY DTC TROUBLESHOOTING COMPLETED
•  Clear the DTC for the instrument cluster using the M-MDS.
•  Retrieve the instrument cluster DTCs using the M-MDS.
•  Is the same DTC displayed?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the instrument cluster.
Go to the next step.
No
Go to the next step.
3
VERIFY IF OTHER DTCs DISPLAYED
•  Are any other DTCs displayed?
Yes
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
No
DTC troubleshooting completed.