DTC U3003:16, U3003:17 [THEFT-DETERRENT SYSTEM]


id0902g7850900

DESCRIPTION

Theft-deterrent control module power supply circuit malfunction

DETECTION CONDITION
•  Theft-deterrent control module power supply voltage is other than 9—16 V.
POSSIBLE CAUSE
•  Battery malfunction
•  Generator malfunction
•  BCM connector or terminals malfunction
•  Open circuit or short to ground in theft-deterrent control module power supply circuit
―  Short to ground in wiring harness between BCM terminal 2A and battery positive terminal
―  ROOM 15 A fuse malfunction
―  MAIN 150 A fuse malfunction
―  Open circuit in wiring harness between BCM terminal 2A and battery positive terminal
•  BCM malfunction
•  Theft-deterrent control module connector or terminals malfunction
•  Short to ground in wiring harness between theft-deterrent control module terminal W and BCM terminal 5H
•  Open circuit in wiring harness between theft-deterrent control module terminal W and BCM terminal 5H
•  Theft-deterrent control module malfunction


Diagnostic Procedure

Step

Inspection

Action

1
PERFORM PCM DTC INSPECTION
•  Perform the PCM DTC inspection using the M-MDS.
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
Go to the next step.
2
INSPECT BATTERY
•  Inspect the battery.
•  Is there any malfunction?
Yes
Recharge or replace the battery, then go to Step 10.
No
Go to the next step.
3
INSPECT GENERATOR
•  Inspect the generator.
•  Is there any malfunction?
Yes
Replace the generator, then go to Step 10.
No
Go to the next step.
4
INSPECT BCM CONNECTOR AND TERMINALS
•  Turn the ignition switch to the OFF position.
•  Disconnect the negative battery cable.
•  Disconnect the BCM connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 10.
No
Go to the next step.
5
INSPECT THEFT-DETERRENT CONTROL MODULE POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT AND SHORT TO GROUND
•  Verify that the BCM connector is disconnected.
•  Reconnect the negative battery cable.
•  Measure the voltage at the BCM terminal 2A (wiring harness-side).
•  Is the voltage B+?
Yes
Go to the next step.
No
Inspect the ROOM 15 A fuse and MAIN 150 A fuse.
•  If the fuse is melt:
―  Repair or replace the wiring harness for a possible short to ground.
―  Replace the fuse.
•  If the fuse is deterioration:
―  Replace the fuse.
•  If the fuse is normal:
―  Repair or replace the wiring harness for a possible open circuit.
Go to Step 10.
6
INSPECT BCM
•  Disconnect the negative battery cable.
•  Make sure to reconnect all disconnected connectors.
•  Reconnect the negative battery cable.
•  Measure the voltage at the following terminals (wiring harness-side):
―  BCM terminal 2A
―  BCM terminal 5H
•  Is the voltage normal?
Yes
Go to the next step.
No
Replace the BCM, then go to Step 10.
7
INSPECT THEFT-DETERRENT CONTROL MODULE CONNECTOR AND TERMINALS
•  Disconnect the negative battery cable.
•  Disconnect the theft-deterrent control module connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 10.
No
Go to the next step.
8
INSPECT THEFT-DETERRENT CONTROL MODULE POWER SUPPLY CIRCUIT FOR SHORT TO GROUND
•  Verify that the theft-deterrent control module connector is disconnected.
•  Inspect for continuity between the theft-deterrent control module terminal W (wiring harness-side) and body ground.
•  Is there continuity?
Yes
Repair or replace the wiring harness for a possible short to ground, then go to Step 10.
No
Go to the next step.
9
INSPECT THEFT-DETERRENT CONTROL MODULE POWER SUPPLY CIRCUIT FOR OPEN CIRCUIT
•  Verify that the theft-deterrent control module connector is disconnected.
•  Inspect for continuity between the theft-deterrent control module terminal W (wiring harness-side) and BCM terminal 5H (wiring harness-side).
•  Is there continuity?
Yes
Go to the next step.
No
Repair or replace the wiring harness for a possible short to ground, then go to the next step.
10
VERIFY TROUBLESHOOTING COMPLETED
•  Make sure to reconnect all disconnected connectors.
•  Reconnect the negative battery cable.
•  Clear the DTC using the M-MDS.
•  Perform the theft-deterrent control module DTC inspection using the M-MDS.
•  Is the same DTC present?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the theft-deterrent control module.
Go to the next step.
No
Go to the next step.
11
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.