DTC U3000:4A [BLIND SPOT MONITORING (BSM) CONTROL MODULE CONNECTOR 10-PIN TYPE]
id0902q3393500
Description |
BSM OFF switch circuit malfunction |
---|---|
Detection condition
|
• BSM control module (LH) detects a short to ground in the BSM OFF switch circuit for 180 s or more.
|
Fail-safe function
|
• Blind spot monitoring (BSM) system is stopped.
|
Possible cause
|
• BSM OFF switch connector or terminal malfunction
• BSM OFF switch malfunction
• BSM control module (LH) connector or terminal malfunction
• Short to ground in wiring harness between BSM control module (LH) terminal H and BSM OFF switch terminal I (L.H.D.)/C (R.H.D.)
• BSM control module (LH) malfunction
|
![]() |
Diagnostic procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
INSPECT BSM OFF SWITCH CONNECTOR CONDITION
• Switch the ignition off.
• Disconnect the negative battery cable.
• Disconnect the BSM OFF switch connector.
• Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
• Is the connector normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the connector, then go to Step 5.
|
||
2
|
INSPECT BSM OFF SWITCH
• Inspect the BSM OFF switch.
• Is the BSM OFF switch normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the cluster switch, then go to Step 5.
|
||
3
|
INSPECT BSM CONTROL MODULE (LH) CONNECTOR CONDITION
• Disconnect the BSM control module (LH) connector.
• Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.
• Is the connector normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the connector, then go to Step 5.
|
||
4
|
INSPECT BSM OFF SWITCH SIGNAL CIRCUIT FOR SHORT TO GROUND
• Verify that the BSM OFF switch and BSM control module (LH) connectors are disconnected.
• Inspect for continuity between BSM OFF switch terminal I (L.H.D.)/C (R.H.D.) (wiring harness-side) and body ground.
• Is there continuity?
|
Yes
|
Refer to the wiring diagram and verify whether or not there is a common connector between BSM control module (LH) terminal H and BSM OFF switch terminal I (L.H.D.)/C (R.H.D.).
If there is a common connector:
• Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
• Repair or replace the malfunctioning part.
If there is no common connector:
• Repair or replace the wiring harness which has a short to ground.
Go to the next step.
|
No
|
Go to the next step.
|
||
5
|
VERIFY DTC TROUBLESHOOTING COMPLETED
• Always reconnect all disconnected connectors.
• Reconnect the negative battery cable.
• Clear the DTC for the BSM control module (LH) using the M-MDS.
• Switch the ignition ON (engine off or on) and wait for 180 s or more.
• Retrieve the BSM control module (LH) DTCs using the M-MDS.
• Is the same DTC displayed?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the BSM control module (LH).
Go to the next step.
|
No
|
Go to the next step.
|
||
6
|
VERIFY IF OTHER DTCs DISPLAYED
• Are any other DTCs displayed?
|
Yes
|
Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
DTC troubleshooting completed.
|