DTC TABLE [HEAT PUMP CONTROL UNIT]
id0702l5717800
DTC |
System malfunction location |
Warning/indicator light |
Fail-safe function |
Drive cycle |
Self test type*1 |
Memory function |
Page |
---|---|---|---|---|---|---|---|
B152D:11
|
Malfunction of circuit of temperature sensor of refrigerant line for evaporator outlet
|
—
|
×
|
—
|
C, D
|
×
|
|
B152D:15
|
Malfunction of circuit of temperature sensor of refrigerant line for evaporator outlet
|
—
|
×
|
—
|
C, D
|
×
|
|
B1530:87
|
Heat pump control unit (internal malfunction)
|
—
|
×
|
—
|
C, D
|
×
|
|
B1531:13
|
Electric expansion valve circuit malfunction
|
—
|
×
|
—
|
C, D
|
×
|
|
B1532:11
|
Electric expansion valve circuit malfunction
|
—
|
×
|
—
|
C, D
|
×
|
|
P1433:11
|
Circuit malfunction of temperature sensor of refrigerant line for condenser outlet
|
—
|
×
|
—
|
C, D
|
×
|
|
P1434:15
|
Circuit malfunction of temperature sensor of refrigerant line for condenser outlet
|
—
|
×
|
—
|
C, D
|
×
|
|
P2612:14
|
Malfunction of circuit of 2way valve for refrigerant
|
—
|
×
|
—
|
C, D
|
×
|
|
P2613:12
|
Malfunction of circuit of 2way valve for refrigerant
|
—
|
×
|
—
|
C, D
|
×
|
|
P1A2C:14
|
Malfunction of circuit of 3way valve for refrigerant
|
—
|
×
|
—
|
C, D
|
×
|
|
P1A2D:12
|
Malfunction of circuit of 3way valve for refrigerant
|
—
|
×
|
—
|
C, D
|
×
|
|
U0076:88
|
Unit communication error (CAN bus No.3)
|
—
|
—
|
—
|
C, D
|
×
|
|
U0140:00
|
Communication error with body control module (BCM)
|
—
|
×
|
—
|
C, D
|
×
|
|
U0164:00
|
Communication error with dash-electrical supply unit
|
—
|
×
|
—
|
C, D
|
×
|
|
U0422:68
|
Error signal received from body control module (BCM)
|
—
|
×
|
—
|
C, D
|
×
|
|
U0424:68
|
Error signal received from dash-electrical supply unit
|
—
|
×
|
—
|
C, D
|
×
|
|
U2133:00
|
Communication error with climate control unit
|
—
|
—
|
—
|
C, D
|
×
|
|
U2300:54
|
Heat pump control unit configuration error
|
—
|
×
|
—
|
C, D
|
×
|
|
U2300:55
|
Heat pump control unit configuration error
|
—
|
×
|
—
|
C, D
|
×
|
|
U2300:56
|
Heat pump control unit configuration error
|
—
|
×
|
—
|
C, D
|
×
|
|
U2300:64
|
Heat pump control unit configuration error
|
—
|
×
|
—
|
C, D
|
×
|
|
U2513:68
|
Error signal received from climate control unit
|
—
|
—
|
—
|
C, D
|
×
|
|
U3003:16
|
Heat pump control unit low power supply voltage input
|
—
|
×
|
—
|
C, D
|
×
|
|
U3003:17
|
Heat pump control unit high power supply voltage input
|
—
|
×
|
—
|
C, D
|
×
|