DTC TABLE [HEAT PUMP CONTROL UNIT]


id0702l5717800

×: Applicable
—: Not applicable or not illuminated

DTC

System malfunction location

Warning/indicator light

Fail-safe function

Drive cycle

Self test type*1

Memory function

Page

B152D:11
Malfunction of circuit of temperature sensor of refrigerant line for evaporator outlet
×
C, D
×
B152D:15
Malfunction of circuit of temperature sensor of refrigerant line for evaporator outlet
×
C, D
×
B1530:87
Heat pump control unit (internal malfunction)
×
C, D
×
B1531:13
Electric expansion valve circuit malfunction
×
C, D
×
B1532:11
Electric expansion valve circuit malfunction
×
C, D
×
P1433:11
Circuit malfunction of temperature sensor of refrigerant line for condenser outlet
×
C, D
×
P1434:15
Circuit malfunction of temperature sensor of refrigerant line for condenser outlet
×
C, D
×
P2612:14
Malfunction of circuit of 2way valve for refrigerant
×
C, D
×
P2613:12
Malfunction of circuit of 2way valve for refrigerant
×
C, D
×
P1A2C:14
Malfunction of circuit of 3way valve for refrigerant
×
C, D
×
P1A2D:12
Malfunction of circuit of 3way valve for refrigerant
×
C, D
×
U0076:88
Unit communication error (CAN bus No.3)
C, D
×
U0140:00
Communication error with body control module (BCM)
×
C, D
×
U0164:00
Communication error with dash-electrical supply unit
×
C, D
×
U0422:68
Error signal received from body control module (BCM)
×
C, D
×
U0424:68
Error signal received from dash-electrical supply unit
×
C, D
×
U2133:00
Communication error with climate control unit
C, D
×
U2300:54
Heat pump control unit configuration error
×
C, D
×
U2300:55
Heat pump control unit configuration error
×
C, D
×
U2300:56
Heat pump control unit configuration error
×
C, D
×
U2300:64
Heat pump control unit configuration error
×
C, D
×
U2513:68
Error signal received from climate control unit
C, D
×
U3003:16
Heat pump control unit low power supply voltage input
×
C, D
×
U3003:17
Heat pump control unit high power supply voltage input
×
C, D
×

*1  :C: CMDTC self-test, D: ODDTC self-test