TEMPERATURE SENSOR OF REFRIGERANT LINE FOR ELECTRIC COMPRESSOR OUTLET INSPECTION [FULL-AUTO AIR CONDITIONER]


id0740a1702900

1.  Disconnect the negative lead-acid battery terminal. (See NEGATIVE LEAD-ACID BATTERY TERMINAL DISCONNECTION/CONNECTION.)

2.  Remove the temperature sensor of refrigerant line for electric compressor outlet. (See TEMPERATURE SENSOR OF AIR FOR PTC/TEMPERATURE SENSOR OF REFRIGERANT LINE FOR ELECTRIC COMPRESSOR OUTLET REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].)

3.  Measure the temperature around the temperature sensor of refrigerant line for electric compressor outlet and measure the resistance between the temperature sensor of refrigerant line for electric compressor outlet terminals C and D

a30jjw00000102

•  If the characteristics of the ambient temperature sensor are not as shown in the graph, replace the ambient temperature sensor. (See TEMPERATURE SENSOR OF AIR FOR PTC/TEMPERATURE SENSOR OF REFRIGERANT LINE FOR ELECTRIC COMPRESSOR OUTLET REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].)
a30jjw00000103