POSITION MEMORY SWITCH INSPECTION
id091300701000
1. Switch the main power OFF.
2. Disconnect the negative lead-acid battery terminal and wait for 1 min or more. (See NEGATIVE LEAD-ACID BATTERY TERMINAL DISCONNECTION/CONNECTION.)
3. Remove the position memory switch. (See POSITION MEMORY SWITCH REMOVAL/INSTALLATION.)
4. Verify that the resistance and continuity between the position memory switch terminals is as indicated in the table.
a30zzw00002404
|
a30zzw00000951
|