LIFTGATE OPENER SWITCH INSPECTION
id091400701000
1. Disconnect the negative lead-acid battery terminal. (See NEGATIVE LEAD-ACID BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Remove the liftgate opener switch. (See LIFTGATE OPENER SWITCH REMOVAL/INSTALLATION.)
3. Verify the continuity of liftgate opener switch terminals A and B.
a30zzw00000780
|