LIFTGATE OPENER SWITCH INSPECTION


id091400701000

1.  Disconnect the negative lead-acid battery terminal. (See NEGATIVE LEAD-ACID BATTERY TERMINAL DISCONNECTION/CONNECTION.)

2.  Remove the liftgate opener switch. (See LIFTGATE OPENER SWITCH REMOVAL/INSTALLATION.)

3.   Verify the continuity of liftgate opener switch terminals A and B.

a30zzw00000780

•  If not as indicated in the table, replace the liftgate opener switch. (See LIFTGATE OPENER SWITCH REMOVAL/INSTALLATION.)