RELAY INSPECTION


id092100701500


Relay Type

Connector type

Part name

Type A
•  WINDSHIELD WIPER DE-ICER RELAY
•  HEADLIGHT CLEANER RELAY
•  MAIN RELAY No.1
•  MAIN RELAY No.2
•  IG1 RELAY No.1
•  IG1 RELAY No.2
•  ACC RELAY
•  REAR WINDOW DEFOGGER RELAY
•  HEADLIGHT RELAY
•  HORN RELAY
•  QBC CONTACTOR DRIVE RELAY (P)
•  QBC CONTACTOR DRIVE RELAY (N)
•  DMCM RELAY
•  ELECTRIC WATER PUMP RELAY
•  A/C RELAY
Type B
•  CHARGER RELAY
Type C
•  COOLING FAN RELAY
•  BLOWER RELAY


Type A

1.  Remove the relay.

(See RELAY LOCATION [(E)].)

2.  Verify the continuity between relay terminals C and D.

a30zzw00000954

•  If it can be verified, replace the relay.
(See RELAY LOCATION [(E)].)
•  If it cannot be verified, go to the next step.

3.  Verify the continuity between relay terminals E and A.

•  If it can be verified, go to the next step.
•  If it cannot be verified, replace the relay.
(See RELAY LOCATION [(E)].)

4.  Apply battery voltage to relay terminal E, and connect terminal A to ground.

5.  Verify the continuity between relay terminals C and D.

•  If it cannot be verified, replace the relay.
(See RELAY LOCATION [(E)].)


Type B

1.  Remove the relay.(See RELAY LOCATION [(E)].)

2.  Verify the continuity between relay terminals C and D.

a30zzw00000955

•  If it can be verified, replace the relay.(See RELAY LOCATION [(E)].)
•  If it cannot be verified, go to the next step.

3.  Verify the continuity between the relay terminals E and A.

•  If it can be verified, go to the next step.
•  If it cannot be verified, replace the relay.(See RELAY LOCATION [(E)].)

4.  Verify the continuity between the relay terminals B and D.

•  If it can be verified, go to the next step.
•  If it cannot be verified, replace the relay.(See RELAY LOCATION [(E)].)

5.  Apply battery voltage to relay terminal E, and connect terminal A to ground.

6.  Verify the continuity between relay terminals C and D.

•  If it cannot be verified, replace the relay.(See RELAY LOCATION [(E)].)


Type C

1.  Remove the relay.

(See RELAY LOCATION [(E)].)

2.  Verify the continuity between the relay terminals C and A.

a30zzw00000956

•  If it can be verified, replace the relay.
(See RELAY LOCATION [(E)].)
•  If it cannot be verified, go to the next step.

3.  Verify the continuity between the relay terminals D and B.

•  If it can be verified, go to the next step.
•  If it cannot be verified, replace the relay.
(See RELAY LOCATION [(E)].)

4.  Apply battery voltage to relay terminal D, and connect terminal B to ground.

5.  Verify the continuity between relay terminals C and A.

•  If it cannot be verified, replace the relay.
(See RELAY LOCATION [(E)].)