CHARGE PORT LID OPEN/CLOSE SENSOR INSPECTION


id304200000500

1.  Disconnect the negative lead-acid battery terminal. (See NEGATIVE LEAD-ACID BATTERY TERMINAL DISCONNECTION/CONNECTION.)

2.  Disconnect the charge port-electrical supply unit connector.

3.  Verify that the continuity is as indicated in the table.

a30zzw00004705

a30zzw00004706
•  If the continuity is not as indicated in the table, replace the charge lid box assembly. (See CHARGE LID BOX ASSEMBLY REMOVAL/INSTALLATION.)