1. Inspect the speedometer by setting it to check code 12 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)
1. Adjust the tire pressure to the specification.
2. Using a speedometer tester, verify that the tester reading is as indicated in the table below.
Speedometer tester indication (km/h)
|
Allowable range (km/h)
|
---|---|
20
|
20-25
|
40
|
40-45
|
60
|
60-66
|
80
|
81-87
|
100
|
101-108
|
120
|
121-129
|
140
|
142-149
|
Speedometer tester indication (mph)
|
Allowable range (mph)
|
---|---|
10
|
10-13
|
20
|
20-23
|
30
|
30-34
|
40
|
40-44
|
50
|
50-55
|
60
|
60-65
|
70
|
70-75
|
80
|
81-86
|
3. Verify that the speedometer reading is within the range indicated in the table.
1. Inspect the tachometer by setting it to check code 13 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)
1. Connect the M-MDS to the DLC-2 connector.
2. After the vehicle is identified, select the following items from the initial screen of the M-MDS.
3. Compare the data monitor item (IC_TACHO) with the tachometer indication.
1. Inspect the fuel gauge by setting it to check code 23 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)
1. Inspect the water temperature gauge by setting it to check code 25 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)
1. Inspect the oil pressure gauge by setting it to check code 28 of the input/output check mode. (See INSTRUMENT CLUSTER INPUT/OUTPUT CHECK MODE.)