DTC TABLE [HANDS-FREE TELEPHONE (HF/TEL) SYSTEM]


id0902g0363000

Screen display

Malfunction description

Inferred cause/verified content

Reference

DTC (When starting on-board diagnostic function)

26: Er81
HF/TEL function does not operate.
CAN system
26: Er82
Sound from microphone not heard
Short to power supply in wiring harness between microphone (Input signal) and HF/TEL unit
26: Er83
Sound from microphone not heard
Short to GND/power supply in microphone power supply circuit
26: Er84
Call transmission and receiving is impossible
Any of the following is detected:
•  The microphone power supply circuit is not connected.
•  Open circuit in the microphone input circuit
•  Microphone input circuit short to body ground
26: Er85
Call transmission and receiving is impossible
•  Poor contact in the voice recognition/hands-free switch or HF/TEL unit connector
•  Voice recognition/hands-free switch malfunction
26: Er86
HF/TEL function does not operate.
HF/TEL unit malfunction
Replace the HF/TEL unit.
no Err
DTC is not recorded.