M POSITION SWITCH INSPECTION [SJ6A-EL]
id051311500000
Continuity Inspection
1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Remove the following parts:
3. Disconnect the selector lever component connector.
amxuuw00002843
|
4. Verify that the continuity between selector lever component terminals E and H.
adejjw00010660
|
M position switch specification
Test condition |
Continuity |
---|---|
Selector lever is in the M position.
|
Continuity
|
Selector lever is not in the M position.
|
No continuity
|