AIR INTAKE MODE DOES NOT CHANGE [CLIMATE CONTROL SYSTEM]


id0703k2700500

DESCRIPTION
•  Air intake mode does not change when switching REC/FRESH mode
POSSIBLE CAUSE
•  Air intake actuator malfunction
•  Open or short circuit in wiring harness between climate control unit and air intake actuator
•  Climate control unit malfunction
•  Air intake link malfunction
•  Air intake door malfunction
•  Restriction in A/C unit

•  When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while performing the inspection to discover whether poor contact points are the cause of any intermittent malfunctions. If there is a problem, inspect make sure connectors, terminals and wiring harnesses are connected correctly and undamaged.

Diagnostic Procedure

Step

Inspection

Action

1
INSPECT AIR INTAKE ACTUATOR
•  Inspect the following item using the M-MDS A/C operation check mode function.
―  Air Intake Actuator
•  Does the air intake actuator operate?
Yes
Go to Step 7.
No
Go to the next step.
2*
INSPECT TO SEE WHETHER MALFUNCTION IS IN AIR INTAKE ACTUATOR OR ELSEWHERE
•  Disconnect the air intake actuator connector.
•  Measure the voltages at the following climate control unit terminals.
―  Terminal U (FRESH motor drive signal)
―  Terminal S (RECIRCULATE motor drive signal)
•  Are voltages normal?
Yes
Go to the next step.
No
Go to Step 4.
3
INSPECT AIR INTAKE ACTUATOR
•  Is the air intake actuator normal?
Yes
Go to Step 7.
No
Replace the air intake actuator.
Then go to Step 9.
4*
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO B+ BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
•  Air intake actuator connector disconnected.
•  Measure the voltages at the following air intake actuator terminals.
―  Terminal A (FRESH motor drive signal)
―  Terminal B (RECIRCULATE motor drive signal)
•  Are voltages approx. 0 V?
Yes
Go to the next step.
No
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal.
If there is a common connector:
•  Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to power supply.
•  Repair or replace the malfunctioning part.
If there is no common connector:
•  Repair or replace the wiring harness which has a short to power supply.
Go to Step 9.
5*
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (SHORT TO GROUND BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
•  Climate control unit and air intake actuator connectors disconnected.
•  Switch the ignition off.
•  Inspect for continuity at the following terminals between the air intake actuator and ground.
―  Terminal A (FRESH motor drive signal)
―  Terminal B (RECIRCULATE motor drive signal)
•  Is there continuity?
Yes
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal.
If there is a common connector:
•  Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.
•  Repair or replace the malfunctioning part.
If there is no common connector:
•  Repair or replace the wiring harness which has a short to ground.
Go to Step 9.
No
Go to the next step.
6*
INSPECT TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (LACK OF CONTINUITY OR OPEN BETWEEN CLIMATE CONTROL UNIT AND AIR INTAKE ACTUATOR) OR ELSEWHERE
•  Climate control unit and air intake actuator connectors disconnected.
•  Inspect for continuity at the following terminals between the air intake actuator and climate control unit.
―  Terminal A—U (FRESH motor drive signal)
―  Terminal B—S(RECIRCULATE motor drive signal)
•  Is there continuity?
Yes
Replace the climate control unit, then go to Step 9.
No
Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and air intake actuator terminal.
If there is a common connector:
•  Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness.
•  Repair or replace the malfunctioning part.
If there is no common connector:
•  Repair or replace the wiring harness.
Go to Step 9.
7
INSPECT AIR INTAKE LINK
•  Inspect the air intake link.
―  Is there grease on link?
―  Are the links securely and properly installed?
―  Are the links free of obstructions and hindrances?
•  Are the above items normal?
Yes
Go to the next step.
No
Apply grease to the links. If any the links are damaged, replace the air intake actuator, then go to Step 9.
8
INSPECT TO SEE WHETHER MALFUNCTION IS IN CLIMATE CONTROL UNIT OR AIR INTAKE DOOR
•  Inspect the A/C unit air intake door.
―  Is the door free of obstructions, cracks, and damage?
―  Are the doors securely and properly installed?
•  Are the above items normal?
Yes
Go to the next step.
No
Remove obstruction, or install the doors in the proper position. If any doors are cracked or damaged, replace them, then go to the next step.
9
VERIFY THAT MALFUNCTION SYMPTOMS DO NOT RECUR AFTER REPAIR
•  Does the air intake mode change smoothly?
Yes
Troubleshooting completed. Explain repairs to customer.
No
Recheck malfunction symptoms, then repeat from Step 1 if the malfunction recurs.