AIR INTAKE ACTUATOR INSPECTION [FULL-AUTO AIR CONDITIONER]
id0740a1801500
L.H.D.
1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Remove the following parts:
3. Disconnect the connector.
amxzzw00003081
|
4. While pressing the clip tabs in the direction of arrows (1) shown in the figure, press the clip in the direction of arrow (2) to detach the clip tabs from the bracket.
5. Remove the clip.
6. Disconnect the connector.
amxuuw00003917
|
7. Remove the air intake actuator. (See AIR INTAKE ACTUATOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].)
8. Apply battery positive voltage and connect the ground to the air intake actuator terminals as indicated in the table below and verify the operation condition.
B+ Terminal |
Ground Terminal |
Operation |
---|---|---|
A
|
B
|
RECIRCULATE → FRESH
|
B
|
A
|
FRESH → RECIRCULATE
|
amxuuw00004906
|
R.H.D.
1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
2. Remove the following parts:
3. Disconnect the connectors.
amxzzw00003082
|
4. While pressing the clip tabs in the direction of arrows (1) shown in the figure, press the clip in the direction of arrow (2) to detach the clip tabs from the bracket.
5. Remove the clip.
6. Disconnect the connector.
amxzzw00003083
|
7. Remove the air intake actuator. (See AIR INTAKE ACTUATOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].)
8. Apply battery positive voltage and connect the ground to the air intake actuator terminals as indicated in the table below and verify the operation condition.
B+ Terminal |
Ground Terminal |
Operation |
---|---|---|
A
|
B
|
RECIRCULATE → FRESH
|
B
|
A
|
FRESH → RECIRCULATE
|
amxzzw00003479
|