FUEL-FILLER LID LOCK ACTUATOR INSPECTION
id091400009600
1. Open the fuel-filler lid.
2. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION.)
3. Remove the trunk end trim. (See TRUNK END TRIM REMOVAL/INSTALLATION.)
4. Partially peel back the trunk side trim (LH) to the position allowing removal of the fuel-filler lid lock actuator. (See TRUNK SIDE TRIM REMOVAL/INSTALLATION.)
5. Disconnect the fuel-filler lid lock actuator connector. (See FUEL-FILLER LID LOCK ACTUATOR REMOVAL/INSTALLATION.)
6. Apply battery positive voltage and connect the ground to the fuel-filler lid lock actuator terminals as indicated in the table below and verify the operation condition.
ardjjw00005033
|
B+ terminal |
Ground terminal |
Operation |
---|---|---|
A
|
B
|
Lock
|
B
|
A
|
Unlock
|