FUEL LINE PRESSURE INSPECTION [L8, LF]
id0114a3800500
1. Follow “BEFORE SERVICE PRECAUTION” before performing any work operations to prevent fuel from spilling from the fuel system. (See BEFORE SERVICE PRECAUTION [L8, LF].)
2. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [L8, LF].)
3. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [L8, LF] .)
4. Disconnect the quick release connector. (See QUICK RELEASE CONNECTOR (FUEL SYSTEM) REMOVAL/INSTALLATION [L8, LF].)
5. Turn the lever of the SST parallel to the hose as shown in the figure.
amxzzw00000817
|
6. Insert the SST quick release connector into the fuel pipe until a click is heard.
7. Verify that the quick release connector is firmly connected by pulling it by hand.
8. Start the fuel pump using the following procedure:
amxzzw00000818
|
amxzzw00000819
|
amxzzw00000820
|
9. Operate the fuel pump for 10 s.
10. Measure the fuel line pressure.
11. Stop the fuel pump using the following procedure:
12. Measure the fuel hold pressure after 5 min.
13. Follow “BEFORE SERVICE PRECAUTION” before performing any work operations to prevent fuel from spilling from the fuel system. (See BEFORE SERVICE PRECAUTION [L8, LF].)
14. Disconnect the SST.
15. Connect the quick release connector to the fuel distributor. (See QUICK RELEASE CONNECTOR (FUEL SYSTEM) REMOVAL/INSTALLATION [L8, LF].)
16. Complete the “AFTER SERVICE PRECAUTION”. (See AFTER SERVICE PRECAUTION [L8, LF].)