NO.31 M RANGE POSITION INDICATOR LIGHT DOES NOT ILLUMINATE IN M RANGE AND/OR IN D RANGE WITH DIRECT MODE/M RANGE POSITION INDICATOR LIGHT ILLUMINATES IN D RANGE WHILE NOT IN DIRECT MODE [SJ6A-EL]
id050307813500
31
|
M range position indicator light does not illuminate in M range and/or in D range with direct mode/M range position indicator light illuminates in D range while not in direct mode
|
DESCRIPTION
|
• M range position indicator light in instrument cluster does not illuminate in M range and/or in D range in direct mode when ignition switch is in ON position.
• M range position indicator light illuminates in D range while not in direct mode when ignition switch is in ON position.
|
POSSIBLE CAUSE
|
• M range switch (built-in selector lever) malfunction
• Steering shift switch malfunction
• Open or short circuit in wiring harness between M range switch (built-in selector lever) and TCM
• Open or short circuit in wiring harness between steering shift switch and TCM
|
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Access the TCM PID MNL SW using the M-MDS.
• Monitor the MLN SW PID with move the selector lever to all position and range.
• Does the MNL SW PID indicate properly?
|
Yes
|
Go to the next step.
|
No
|
Inspect the M range switch.
If the M range switch has a malfunction:
• Replace the selector lever component.
If the M range switch is normal:
• Inspect for continuity between manual switch terminal B and TCM terminal 2G.
• Repair or replace the suspected wiring harness.
|
||
2
|
• Access the TCM PIDs UP SW and DWN SW using the M-MDS.
• Monitor the UP SW and DWN SW PIDs by pressing the steering shift switch while the selector lever is in the D range.
• Are the UP SW and DWN SW PIDs indicated correctly?
|
Yes
|
Inspect the instrument cluster using the input/output test mode.
Replace the instrument cluster, if necessary.
|
No
|
Inspect the steering shift switch.
If the steering shift switch has a malfunction:
• Replace the steering shift switch.
If the steering shift switch is normal:
• Inspect for continuity between the following terminals:
• Repair or replace the suspected wiring harness.
|
||
3
|
• Verify test results.
|