DTC B294D/B294E [POWER RETRACTABLE HARDTOP]
id0902j2861600
DTC |
B294D |
Roof motor opening angle does not match (Pulse count number does not match) |
---|---|---|
B294E |
Deck panel motor opening angle does not match (Pulse count number do not match) |
|
DETECTION CONDITION
|
• The left and right pulse count number exceeds a certain level
|
|
POSSIBLE CAUSE
|
• Foreign material caught in mechanism
• Damage to the link
• Roof/deck panel motor malfunction
• Open short circuit in wiring harness between roof/deck panel motor and power retractable hardtop control module
|
|
![]() |
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
FOREIGN MATERIAL INSPECTION
• Is there any malfunction which stops the motor mechanically?
|
Yes
|
Go to the next step.
|
No
|
Remove the foreign material.
|
||
2
|
INSPECT THE ROOF/ROOF MOTOR/DECK PANEL LINK
• Is there any damage to the roof, roof motor, or deck panel link?
|
Yes
|
Go to the next step.
|
No
|
Replace the middle roof panel or deck panel link.
|
||
3
|
INSPECT THE ROOF/DECK PANEL MOTOR
• Turn the ignition switch to the LOCK position.
• Disconnect the negative battery cable.
• Inspect the roof/deck panel motor.
(See ROOF MOTOR INSPECTION.)
(See DECK PANEL MOTOR INSPECTION.)
• Is the roof/deck panel motor normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the roof/deck panel motor.
|
||
4
|
INSPECT THE WIRING HARNESS BETWEEN ROOF/DECK PANEL MOTOR AND POWER RETRACTABLE HARDTOP CONTROL MODULE
• Disconnect the roof/deck panel motor connector.
• Disconnect the power retractable hardtop control module connector.
• Inspect the following wiring harnesses for an open or short circuit.
• Is the wiring harness normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness.
|
||
5
|
INSPECT THE WIRING HARNESS BETWEEN ROOF/DECK PANEL MOTOR AND POWER RETRACTABLE HARDTOP CONTROL MODULE
• Inspect the sensor power supply wiring harness for an open or short circuit.
• Is the wiring harness normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness.
|
||
6
|
INSPECT THE WIRING HARNESS BETWEEN ROOF/DECK PANEL MOTOR AND POWER RETRACTABLE HARDTOP CONTROL MODULE
• Inspect the sensor communication wiring harness for an open or short circuit.
• Is the wiring harness normal?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness.
|
||
7
|
INSPECT THE WIRING HARNESS BETWEEN ROOF/DECK PANEL MOTOR AND POWER RETRACTABLE HARDTOP CONTROL MODULE
• Inspect the sensor ground wiring harness for an open or short circuit.
• Is the wiring harness normal?
|
Yes
|
Replace the power retractable hardtop control module.
|
No
|
Repair or replace the wiring harness.
|