No.2 AUTO LEVELING SYSTEM DOES NOT ADJUST OPTICAL AXIS OF THE HEADLIGHTS FOR VEHICLE POSTURE [HEADLIGHT AUTO LEVELING SYSTEM]


id0903d0930000

2
Auto leveling system does not adjust optical axis of the headlights for vehicle posture
POSSIBLE CAUSE
•  Headlight leveling actuator malfunction
•  Auto leveling control module malfunction
•  Front and/or rear leveling sensor malfunction
•  Improper installation of front and/or rear auto leveling sensor
•  Open or short circuit in wiring between auto leveling control module terminal R and instrument cluster terminal 2O

Diagnostic procedure

STEP

INSPECTION

ACTION

1
VERIFY AUTO LEVELING WARNING LIGHT ILLUMINATION
•  Turn the ignition switch to ON position.
•  Verify that the auto leveling warning light condition.
•  Does the auto leveling warning light illuminate from turning the ignition switch to ON 3 seconds after?
Yes
Perform the symptom “No.1 Auto leveling warning light illuminates when the ignition switch to ON position” troubleshooting procedure.
No
Go to the next step.
2
INSPECT IF THE MALFUNCTION IS IN AUTO LEVELING SENSOR OR ELSEWHERE
•  Is the malfunction appeared both side?
Yes
Go to Step 5.
No
Go to the next step.
3
INSPECT IF THE MALFUNCTION IS IN WIRING HARNESS BETWEEN AUTO LEVELING CONTROL MODULE AND HEADLIGHT LEVELING ACTUATOR
•  Inspect for open or short circuit in wiring harness at auto leveling function does not operate.
Right-side:
―  Auto leveling control module terminal I—front combination light (right-side) terminal G
―  Auto leveling control module terminal J—front combination light (right-side) terminal F
―  Auto leveling control module terminal L—front combination light (right-side) terminal H
Left-side:
―  Auto leveling control module terminal K—front combination light (left-side) terminal G
―  Auto leveling control module terminal J—front combination light (left-side) terminal F
―  Auto leveling control module terminal L—front combination light (left-side) terminal H
•  Is open or short circuit detected?
Yes
Repair or replace for open or short circuit.
No
Go to the next step.
4
INSPECT IF THE MALFUNCTION IS IN HEADLIGHT LEVELING ACTUATOR OR ELSEWHERE
•  Replace the suspected side front combination light.
•  Does the auto leveling adjust optical axis of the headlight for vehicle posture?
Yes
Troubleshooting completed.
(The malfunction is in headlight leveling actuator.)
No
Replace the auto leveling control module.
5
INSPECT IF THE MALFUNCTION IS IN WIRING HARNESS BETWEEN AUTO LEVELING CONTROL MODULE AND HEADLIGHT LEVELING ACTUATOR
•  Inspect for open or short circuit in wiring harness.
Right-side:
―  Auto leveling control module terminal I—front combination light (right-side) terminal G
―  Auto leveling control module terminal J—front combination light (right-side) terminal F
Left-side:
―  Auto leveling control module terminal K—front combination light (left-side) terminal G
―  Auto leveling control module terminal J—front combination light (left-side) terminal F
•  Is open or short circuit detected?
Yes
Repair or replace for open or short circuit.
No
Go to the next step.
6
INSPECT FRONT AND REAR AUTO LEVELING SENSOR INSTALLATION
•  Inspect front and rear auto leveling sensor installation (bend or damaged of bracket, or dislocated link).
•  Are front and rear auto leveling sensor installed properly?
Yes
Go to the next step.
No
Repair or replace the malfunctioning part, or install properly.
7
INSPECT FRONT AUTO LEVELING SENSOR
•  Inspect the front auto leveling sensor.
•  Is the front auto leveling sensor normal?
Yes
Go to the next step.
No
Replace the front auto leveling sensor.
8
INSPECT REAR AUTO LEVELING SENSOR
•  Inspect the rear auto leveling sensor.
•  Is the rear auto leveling sensor normal?
Yes
Go to the next step.
No
Replace the rear auto leveling sensor.
9
INSPECT IF THE MALFUNCTION IS IN VEHICLE SPEED SIGNAL LINE OR ELSEWHERE
•  Turn the ignition switch to OFF.
•  Disconnect the auto leveling control module connector.
•  Turn the ignition switch to ON position.
•  Measure the voltage between auto leveling control module harness side connector terminal R and GND.
•  Is the voltage B+?
Yes
Repair or replace for short to power supply.
No
Go to the next step.
10
INSPECT IF THE MALFUNCTION IS IN VEHICLE SPEED SIGNAL LINE OR ELSEWHERE
•  Turn the ignition switch to OFF.
•  Disconnect auto leveling control module and instrument cluster connectors.
•  Verify that the continuity for following:
―  Auto leveling control module terminal R-GND (normal condition: not continuity)
―  Auto leveling control module terminal R-instrument cluster terminal 2O (normal condition: continuity)
•  Are there continuity.
Yes
Replace the auto leveling control module.
No
Repair or replace for open or short circuit.