POWER RETRACTABLE HARDTOP CONTROL MODULE INSPECTION
id091600809600
1. Remove the following parts:
2. Attach the tester lead to the power retractable hardtop control module wiring harness-side connector and inspect voltage, continuity, or resistance according to the standard (reference) on the table.
Standard (Reference)
amxzzw00002071
|
Terminal |
Signal |
Connected to |
Test condition |
Standard |
Inspection item |
|
---|---|---|---|---|---|---|
1A
|
Trunk lid opener relay output signal
|
Trunk lid opener relay
|
The deck panel is in the fully closed position.
|
B+
|
• Deck panel limit switch
• Trunk lid opener relay
• Related wiring harness
|
|
The deck panel is not in the fully closed position.
|
1.0 or less
|
|||||
1B
|
—
|
—
|
—
|
—
|
—
|
|
1C
|
Power window input signal
|
Power window main switch
|
Under any condition: Inspect for continuity to power window main switch.
|
Continuity detected
|
• Power window main switch
• Related wiring harness
|
|
1D
|
Top lock input signal
|
Top lock switch
|
Ignition switch is turned to the ON position
|
When the top lock is locked.
|
1.0 or less
|
• Top lock switch
• Related wiring harness
|
When the top lock is unlocked.
|
B+
|
|||||
1E
|
Power window full-open request signal (Output)
|
Power window main switch
|
Under any condition: Inspect for continuity to power window main switch.
|
Continuity detected
|
• Power window main switch
• Related wiring harness
|
|
1F
|
Trunk lid latch switch signal
|
Trunk lid latch switch
|
When the trunk lid is open.
|
1.0 or less
|
• Trunk lid latch switch
• Related wiring harness
|
|
When the trunk lid is closed.
|
B+
|
|||||
1G
|
Hall effect sensor power supply
|
• Roof Motor
• Deck panel motor
|
Ignition switch is turned to the ON position
|
When the roof panel or deck panel is not moving.
|
1.0 or less
|
• Roof Motor
• Deck panel Motor
• Related wiring harness
|
When the roof panel or deck panel is moving.
|
B+
|
|||||
1H
|
Input signal of the roof panel open/close switch
|
Power retractable hardtop switch (hazard warning switch)
|
Ignition switch is turned to the ON position
|
Opening switch on
|
approx. 2.5
|
• Power retractable hardtop switch
• Related wiring harness
|
Closing switch on
|
approx. 3.4
|
|||||
Other
|
approx. 5.0
|
|||||
1I
|
Roof motor hall sensor input signal (RH)
|
Roof motor (RH)
|
When the roof panel is moving.
|
Pulse is output.
|
• Roof motor (RH)
• Related wiring harness
|
|
1J
|
Power supply
|
ROOM 15 A fuse
|
Under any condition
|
B+
|
• ROOM 15 A fuse
• Related wiring harness
|
|
1K
|
Deck panel motor hall sensor input signal (RH)
|
Deck panel motor (RH)
|
When the deck panel is moving.
|
Pulse is output.
|
• Deck panel motor (RH)
• Related wiring harness
|
|
1L
|
—
|
—
|
—
|
—
|
—
|
|
1M
|
Roof motor hall sensor input signal (LH)
|
Roof motor (LH)
|
When the roof panel is moving.
|
Pulse is output.
|
• Roof motor (LH)
• Related wiring harness
|
|
1N
|
—
|
—
|
—
|
—
|
—
|
|
1O
|
Deck panel motor hall sensor input signal (LH)
|
Deck panel motor (LH)
|
When the deck panel is moving.
|
Pulse is output.
|
• Deck panel motor (LH)
• Related wiring harness
|
|
1P
|
—
|
—
|
—
|
—
|
—
|
|
1Q
|
Hall effect sensor GND
|
GND
|
Under any condition: Inspect for continuity to GND.
|
Continuity detected
|
• Related wiring harness
|
|
1R
|
Roof close position switch input signal
|
Power retractable hardtop limit switch
|
Ignition switch is turned to the ON position
|
When the roof panel is fully closed.
|
1.0 or less
|
• Power retractable hardtop limit switch
• Related wiring harness
|
When the roof panel is not fully closed.
|
B+
|
|||||
1S
|
CAN-H
|
—
|
Because this terminal is for communication, good/no good judgment by terminal voltage is not possible.
|
—
|
• Related wiring harnesses
|
|
1T
|
Roof open position switch input signal
|
Power retractable hardtop limit switch
|
Ignition switch is turned to the ON position
|
When the roof panel is fully open.
|
1.0 or less
|
• Power retractable hardtop limit switch
• Related wiring harness
|
When the roof panel is not fully open.
|
B+
|
|||||
1U
|
CAN-L
|
—
|
Because this terminal is for communication, good/no good judgment by terminal voltage is not possible.
|
—
|
• Related wiring harnesses
|
|
1V
|
Signal GND
|
Power retractable hardtop limit switch/deck panel limit switch
|
Ignition switch is turned to the ON position
|
Under any condition
|
1.0 or less
|
• Related wiring harness
|
1W
|
Signal GND
|
GND
|
Under any condition: Inspect for continuity to GND.
|
Continuity detected
|
• Related wiring harness
|
|
1X
|
IG1
|
ENGINE 15 A fuse
|
Ignition switch is turned to the ON position
|
B+
|
• Related wiring harness
|
|
When the ignition switch is not in the ON position.
|
1.0 or less
|
|||||
2A
|
Power supply
|
Main fuse block
|
Under any condition
|
B+
|
• Related wiring harness
|
|
2B
|
Power supply
|
Main fuse block
|
Under any condition
|
B+
|
• Related wiring harness
|
|
2C
|
Indicator light output signal
|
Power retractable hardtop Indicator light
(hazard warning switch)
|
Ignition switch is turned to the ON position
|
Illuminated
|
1.0 or less
|
• Hazard switch
• Related wiring harness
|
Not illuminated
|
B+
|
|||||
2D
|
—
|
—
|
—
|
—
|
—
|
|
2E
|
Power GND
|
GND
|
Under any condition: Inspect for continuity to GND.
|
Continuity detected
|
• Related wiring harness
|
|
2F
|
Power GND
|
GND
|
Under any condition: Inspect for continuity to GND.
|
Continuity detected
|
• Related wiring harness
|
|
3A
|
Roof motor control (open)
|
Roof motor (RH)
|
Ignition switch is turned to the ON position
|
Roof panel open operation
|
B+
|
• Roof motor (RH)
• Related wiring harness
|
Roof panel close operation
|
1.0 or less*1
|
|||||
Other
|
approx. 2
|
—
|
||||
3B
|
—
|
—
|
—
|
—
|
—
|
|
3C
|
—
|
—
|
—
|
—
|
—
|
|
3D
|
Roof motor control (close)
|
Roof motor (LH)
|
Ignition switch is turned to the ON position
|
Roof panel open operation
|
1.0 or less*1
|
• Roof motor (LH)
• Related wiring harness
|
Roof panel close operation
|
B+
|
|||||
Other
|
approx. 2
|
—
|
||||
3E
|
Deck panel motor control (close)
|
Deck panel motor (RH)
|
Ignition switch is turned to the ON position
|
Deck panel open operation
|
1.0 or less*1
|
• Deck panel motor (RH)
• Related wiring harness
|
Deck panel close operation
|
B+
|
|||||
Other
|
approx. 2
|
|||||
3F
|
Deck panel open position sensor input signal
|
Deck panel limit switch
|
Ignition switch is turned to the ON position
|
When the deck panel is fully open.
|
1.0 or less
|
• Deck panel limit switch
• Related wiring harness
|
When the deck panel is not fully open.
|
B+
|
|||||
3G
|
—
|
—
|
—
|
—
|
—
|
|
3H
|
Deck panel motor control (open)
|
Deck panel motor (LH)
|
Ignition switch is turned to the ON position
|
Deck panel open operation
|
B+
|
• Deck panel motor (LH)
• Related wiring harness
|
Deck panel close operation
|
1.0 or less*1
|
|||||
Other
|
approx. 2
|
|||||
3I
|
Roof motor control (close)
|
Roof motor (RH)
|
Ignition switch is turned to the ON position
|
Roof panel open operation
|
1.0 or less*1
|
• Roof motor (RH)
• Related wiring harness
|
Roof panel close operation
|
B+
|
|||||
Other
|
approx. 2
|
|||||
3J
|
—
|
—
|
—
|
—
|
—
|
|
3K
|
—
|
—
|
—
|
—
|
—
|
|
3L
|
Roof motor control (open)
|
Roof motor (LH)
|
Ignition switch is turned to the ON position
|
Roof panel open operation
|
B+
|
• Roof motor (LH)
• Related wiring harness
|
Roof panel close operation
|
1.0 or less*1
|
|||||
Other
|
approx. 2
|
|||||
3M
|
Deck panel motor control (open)
|
Deck panel motor (RH)
|
Ignition switch is turned to the ON position
|
Deck panel open operation
|
B+
|
• Deck panel motor (RH)
• Related wiring harness
|
Deck panel close operation
|
1.0 or less*1
|
|||||
Other
|
approx. 2
|
|||||
3N
|
—
|
—
|
—
|
—
|
—
|
|
3O
|
Deck panel close position sensor input signal
|
Deck panel limit switch
|
Ignition switch is turned to the ON position
|
Except closed position
|
1.0 or less
|
• Deck panel limit switch
• Related wiring harness
|
Closed position
|
B+
|
|||||
3P
|
Deck panel motor control (close)
|
Deck panel motor (LH)
|
Ignition switch is turned to the ON position
|
Deck panel open operation
|
1.0 or less*1
|
• Deck panel motor (LH)
• Related wiring harness
|
Deck panel close operation
|
B+
|
|||||
Other
|
approx. 2
|
Inspection using an oscilloscope (reference)
amxzzw00002072
|
amxzzw00002073
|