NONRETURN VALVE INSPECTION [MZ-CD 1.6 (Y6)]
id0114c3803600
1. Follow “BEFORE SERVICE PRECAUTION” before performing any work operations to prevent fuel from spilling from the fuel system. (See BEFORE SERVICE PRECAUTION [MZ-CD 1.6 (Y6)].)
2. Disconnect the negative battery cable.
3. Remove the fuel gauge sender unit. (See FUEL GAUGE SENDER UNIT REMOVAL/INSTALLATION [MZ-CD 1.4 DI Turbo, MZ-CD 1.6 (Y6)].)
4. Siphon the fuel from the fuel tank.
5. Verify that the nonreturn valve is closed.