TRANSAXLE RANGE (TR) SWITCH INSPECTION [FN4A-EL]


id051701800900

Caution
•  Water or foreign objects entering the connector can cause a poor connection or corrosion. Be sure not to drop water or foreign objects on the connector when disconnecting it.
•  Do not damage the terminals.

Operating Inspection

1.  Perform the following procedures to inspect the TR switch.

•  If there is any malfunction, adjust the TR switch. (See TRANSAXLE RANGE (TR) SWITCH ADJUSTMENT [FN4A-EL].)
(1)  Verify that the starter operates only when the ignition switch is turned to the START position with the selector lever in P or N position.
(2)  Verify that the back-up lights illuminate when selected to R position with the ignition switch at the ON position.
(3)  Verify that the positions of the selector lever and the indicator are aligned.


Continuity Inspection

1.  Perform the following procedures.

(1)  Disconnect the negative battery cable.
(2)  Disconnect the TR switch connector.
am2zzw00004858

2.  Inspect continuity as indicated in the table.

am2zzw00001028
am2zzw00004859

•  If there is any malfunction, adjust the TR switch. (See TRANSAXLE RANGE (TR) SWITCH ADJUSTMENT [FN4A-EL].)