SECURITY LIGHT: 16, DTC: U0100:87/P1260:00 [IMMOBILIZER SYSTEM (KEYLESS ENTRY SYSTEM)]


id0902e5356800

DTC

Security light flashing pattern

16

Communication error between instrument cluster and PCM (no response)

M-MDS display

Instrument cluster

U0100:87

PCM

P1260:00

POSSIBLE CAUSE
•  Malfunction in wiring harness (CAN line) between instrument cluster and PCM
•  PCM malfunction
•  Instrument cluster malfunction


Diagnostic Procedure

Step

Inspection

Action

1
VERIFY DTCs
•  Clear DTCs using the M-MDS.
•  Verify DTCs using the M-MDS.
•  Is a DTC displayed for either the instrument cluster or PCM, or both?
―  U0001:88
Yes
Repair the malfunctioning part according to the separate DTC inspection.
No
Go to the next step.
2
VERIFY DTCs
•  Clear DTCs using the M-MDS.
•  Verify DTCs using the M-MDS.
•  Are DTCs output?
―  Instrument cluster: U0100:87
―  PCM:P1260:00
Yes
•  Inspect DTC P1260:00.
•  Go to the next step.
No
Go to step 4.
3
VERIFY AFTER REPAIR
•  Clear DTCs using the M-MDS.
•  Verify DTCs using the M-MDS.
•  Are DTCs output again?
―  Instrument cluster: U0100:87
―  PCM:P1260:00
Yes
•  Replace the instrument cluster and program the immobilizer system-related parts.
•  Go to the next step.
No
Go to the next step.
4
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Verify if other DTCs are displayed.
•  Are any other DTCs output?
Yes
Perform the corresponding DTC inspection.
No
DTC troubleshooting completed.