DTC B1A84:41/U0300:00 [INSTRUMENT CLUSTER]
id0902e8999900
DTCs B1A84:41, U0300:00 |
Instrument cluster configuration error |
---|---|
Detection Condition
|
Configuration error
|
Possible Causes
|
Configuration was not done correctly for some reason
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
PERFORM INSTRUMENT CLUSTER CONFIGURATION
• Perform the instrument cluster configuration using the M-MDS.
• Clear the DTC.
• Inspect the instrument cluster DTCs.
• Are DTCs B1A84:41, U0300:00 displayed?
|
Yes
|
Replace the instrument cluster.
Go to the next step.
|
No
|
DTC troubleshooting completed.
|
||
2
|
VERIFY THAT NO OTHER DTCs ARE RECORDED
• Clear DTCs using the M-MDS.
• Inspect the instrument cluster DTCs.
• Are any other DTCs displayed?
|
Yes
|
Perform the corresponding DTC inspection.
|
No
|
DTC troubleshooting completed.
|