NO.1 THE SECURITY LIGHT DISPLAY IS NOT NORMAL [IMMOBILIZER SYSTEM]


id0903f5900400

1

The security light display is not normal.

DESCRIPTION
•  The security light remains illuminated 2 min or more after the ignition switch is turned to the ON position.
•  The security does not illuminate when the ignition switch is turned to the ON position.
•  The security light remains illuminated while the ignition switch is at the LOCK position.
•  The security light does not flash or the flashing interval is abnormal while the ignition switch is at the LOCK position.
POSSIBLE CAUSE
•  Keyless control module malfunction (with advanced keyless and start system)
•  Instrument cluster malfunction
Note
•  If the security light continues to remain illuminated or flashing even after 1 min has elapsed since the ignition switch was turned to the ON position and a DTC is displayed, perform the immobilizer system malfunction diagnosis according to that DTC. (See DTC TABLE [IMMOBILIZER SYSTEM (ADVANCED KEYLESS AND START SYSTEM)].)(See DTC TABLE [IMMOBILIZER SYSTEM (KEYLESS ENTRY SYSTEM)].)
•  While performing immobilizer system security access using the M-MDS, the security light does not illuminate even if the ignition switch is turned to the ON position. Verify the illumination condition of the security light by disconnecting the DLC-2 to release security access.
•  The flashing security light conditions while the ignition switch is in the LOCK position are as follows:
am2zzw00001483

Note
•  Normal operation of the security light is as follows. The light starts flashing every 2 s when the ignition switch is turned from ON to ACC position and the immobilizer system is armed. The light stops flashing when the ignition switch is turned to the ON position with the correct ignition key. At this time, the immobilizer system is disarmed and the security light illuminates for about 3 s and then goes out.

Diagnostic procedure

STEP

INSPECTION

ACTION

1
Verify that the other warning lights in the instrument cluster condition
•  Turn the ignition switch to the ON position.
•  Verify that the other warning lights in the instrument cluster condition.
•  Do the warning lights illumination normal?
Yes
Go to the next step.
No
Refer to the symptom troubleshooting and inspect the instrument cluster.
2
Malfunction condition verification
•  Verify that the security light illumination.
•  Does the security light remains illuminate above 2 min?
Yes
Replace the instrument cluster.
No
Go to the next step.
3
Malfunction condition verification
•  Turn the ignition switch to the LOCK position.
•  Verify that the security light illumination.
•  Does the security light remain illumination?
Yes
Replace the instrument cluster.
No
Go to the next step.
4
Malfunction condition verification
•  Verify that the security light is flashing.
•  Does the security light flash normally?
Yes
Go to the next step.
No
If the security light flashes with DTC patterns, perform the applicable DTC troubleshooting procedure.
If the security light does not flash, replace the instrument cluster.
5
Vehicle specification verification
•  Is the advanced keyless and start system equipped?
Yes
Go to the next step.
No
Replace the instrument cluster.
6
The malfunction location is split into either the keyless control module or the instrument cluster.
Note
•  DTCs could be stored in the keyless control module by performing the following procedure.
•  Turn the ignition switch to the LOCK position.
•  Disconnect the negative battery cable.
•  Disconnect the keyless control module connectors.
•  Connect the negative battery cable.
•  Turn the ignition switch to the ON position.
•  Does the security light illuminate normally?
Yes
Replace the instrument cluster.
No
Replace the keyless control module.