VARIABLE TUMBLE SHUTTER VALVE ACTUATOR INSPECTION [MZR 1.3, MZR 1.5]
id011317803100
Operation inspection
1. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZR 1.3, MZR 1.5].)
2. Remove the variable tumble shutter valve actuator.
3. Connect the battery positive voltage to terminal A or B, and verify that the gear moves.
am2zzw00005224
|
Terminal |
Gear rotation direction |
|
---|---|---|
A |
B |
|
B+
|
Ground
|
Counterclockwise
|
Ground
|
B+
|
Clockwise
|