FUEL PUMP UNIT INSPECTION [MZR 1.3, MZR 1.5]


id011417801100


Continuity Inspection

1.  Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZR 1.3, MZR 1.5].)

2.  Disconnect the fuel pump unit connector.

3.  Inspect for continuity between fuel pump unit terminals A—B.

am2zzw00001406

•  If there is no continuity, replace the fuel pump. (See FUEL PUMP UNIT REMOVAL/INSTALLATION [MZR 1.3, MZR 1.5].)