INTAKE AIR TEMPERATURE (IAT) SENSOR INSPECTION [MZR 1.3, MZR 1.5]
id0140e6802200
1. Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZR 1.3, MZR 1.5].)
2. Disconnect the MAF/IAT sensor connector.
3. Verify that the resistance between MAF/IAT sensor terminals D and E is within the specification.
am2zzw00006064
|
IAT sensor resistance
IAT (°C {°F}) |
Resistance (kilohm) |
---|---|
–20 {–4}
|
13.6—18.4
|
20 {68}
|
2.21—2.69
|
60 {140}
|
0.493—0.667
|
IAT sensor characteristics graph (reference)
am2zzw00006065
|