CLUTCH PEDAL POSITION (CPP) SWITCH INSPECTION [MZ-CD 1.6]


id0140e7801600


Continuity Inspection

1.  Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION [MZ-CD 1.6].)

2.  Disconnect the CPP switch connector.

3.  Verify that the continuity between CPP switch terminals A and B is as indicated in the table. (See CLUTCH PEDAL REMOVAL/INSTALLATION [B65M-R].)

am2zzw00002918

•  If it is not as indicated in the table, replace the CPP switch.
am2zzw00006327