DTC U2100:00 [DYNAMIC STABILITY CONTROL (DSC)]


id0402b2878800

DTC
U2100:00
Configuration data not recorded
DETECTION CONDITION
•  DSC CM detects configuration data not record or data error
POSSIBLE CAUSE
•  DSC CM malfunction

Diagnostic procedure

STEP

INSPECTION

ACTION

1
RECORD THE CONFIGURATION DATA
•  Turn the ignition switch to the off.
•  Turn the ignition switch to the ON position, and maintain this condition for approx. 30 s.
Go to the next step.
2
VERIFY THAT THE SAME DTC IS NOT PRESENT
•  Clear the DTCs from the memory.
•  Are the same DTCs present?
Yes
Repeat the inspection from Step 1.
If the malfunction recurs, replace the DSC CM, then go to the next step.
No
Go to the next step.
3
VERIFY THAT NO OTHER DTCS ARE PRESENT
•  Are any other DTCs output?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.