DTC B10E7:16 [ADVANCED KEYLESS AND START SYSTEM]
id0902e1388300
Description
Possible Causes
System Wiring Diagram
am2zzw00006109
|
Diagnostic Procedure
Step |
Inspection |
Action |
|
---|---|---|---|
1
|
INSPECT KEYLESS CONTROL MODULE CONNECTOR AND TERMINALS
• Turn the ignition switch to the LOCK position.
• Disconnect the negative battery cable.
• Disconnect the keyless control module connector.
• Inspect the connector and terminals (corrosion, damage, pin disconnection).
• Is there any malfunction?
|
Yes
|
Repair or replace the connector or terminals, then go to Step 3.
|
No
|
Go to the next step.
|
||
2
|
INSPECT POWER SUPPLY CIRCUIT (IG1) FOR OPEN CIRCUIT OR SHORT TO GROUND
• Verify that the keyless control module connector is disconnected.
• Reconnect the negative battery cable.
• Turn the ignition switch to the ON position.
• Measure the voltage at the keyless control module terminal 2C (wiring harness-side).
• Is the voltage B+?
|
Yes
|
Go to the next step.
|
No
|
Inspect the ENG 10 A fuse.
• If the fuse is melt:
• If the fuse is deterioration:
• If the fuse is normal:
Go to the next step.
|
||
3
|
VERIFY TROUBLESHOOTING COMPLETED
• Make sure to reconnect all disconnected connectors.
• Reconnect the negative battery cable.
• Clear the DTCs using the M-MDS.
• Perform the keyless control module DTC inspection using the M-MDS.
• Is the same DTC present?
|
Yes
|
Repeat the inspection from Step 1.
• If the malfunction recurs, replace the keyless control module.
Go to the next step.
|
No
|
Go to the next step.
|
||
4
|
VERIFY THAT NO OTHER DTCs ARE PRESENT
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
DTC troubleshooting completed.
|