DTC B10E7:16 [ADVANCED KEYLESS AND START SYSTEM]


id0902e1388300


Description

•  Keyless control module IG1 power voltage malfunction

Possible Causes

•  Keyless control module connector or terminals malfunction
•  Short to ground or open circuit in ignition switch (IG1) circuit
―  Short to ground in wiring harness between ENG 10 A fuse and keyless control module terminal 2C
―  ENG 10 A fuse malfunction
―  Open circuit in wiring harness between battery positive terminal and keyless control module terminal 2C
•  Keyless control module malfunction

System Wiring Diagram

am2zzw00006109

Diagnostic Procedure

Step

Inspection

Action

1
INSPECT KEYLESS CONTROL MODULE CONNECTOR AND TERMINALS
•  Turn the ignition switch to the LOCK position.
•  Disconnect the negative battery cable.
•  Disconnect the keyless control module connector.
•  Inspect the connector and terminals (corrosion, damage, pin disconnection).
•  Is there any malfunction?
Yes
Repair or replace the connector or terminals, then go to Step 3.
No
Go to the next step.
2
INSPECT POWER SUPPLY CIRCUIT (IG1) FOR OPEN CIRCUIT OR SHORT TO GROUND
•  Verify that the keyless control module connector is disconnected.
•  Reconnect the negative battery cable.
•  Turn the ignition switch to the ON position.
•  Measure the voltage at the keyless control module terminal 2C (wiring harness-side).
•  Is the voltage B+?
Yes
Go to the next step.
No
Inspect the ENG 10 A fuse.
•  If the fuse is melt:
―  Repair or replace the wiring harness for a possible short to ground.
―  Replace the malfunctioning fuse.
•  If the fuse is deterioration:
―  Replace the malfunctioning fuse.
•  If the fuse is normal:
―  Repair or replace the wiring harness for a possible open circuit.
Go to the next step.
3
VERIFY TROUBLESHOOTING COMPLETED
•  Make sure to reconnect all disconnected connectors.
•  Reconnect the negative battery cable.
•  Clear the DTCs using the M-MDS.
•  Perform the keyless control module DTC inspection using the M-MDS.
•  Is the same DTC present?
Yes
Repeat the inspection from Step 1.
•  If the malfunction recurs, replace the keyless control module.
Go to the next step.
No
Go to the next step.
4
VERIFY THAT NO OTHER DTCs ARE PRESENT
•  Are any DTCs present?
Yes
Go to the applicable DTC inspection.
No
DTC troubleshooting completed.