DRIVER-SIDE DOOR GLASS CAN BE OPERATED MANUALLY BUT CANNOT BE OPERATED AUTOMATICALLY [POWER WINDOW SYSTEM]


id0903a0069800


Outline

Description
•  Driver-side door glass can be operated manually but cannot be operated automatically.
Possible cause
•  Door glass is manually opened/closed10 times without fully closing it
•  Power window main switch malfunction
•  Door-electrical supply unit (driver's side) malfunction


Diagnostic Procedure

Step

Inspection

Results

Action

1
VERIFY ALL SYSTEM DTCs
•  Perform the DTC inspection.
•  Are any DTCs displayed?
Yes
Repair the malfunctioning location according to the applicable DTC troubleshooting.
No
Go to the next step.
2
PERFORM POWER WINDOW SYSTEM INITIAL SETTING
•  Perform the power window system initial setting.
•  Has the malfunction symptom been eliminated?
Yes
Complete the symptom troubleshooting. (Explain contents of repair to customer)
No
Go to the next step.
3
INSPECT POWER WINDOW MAIN SWITCH FOR MALFUNCTION
•  Inspect the applicable part.
•  Is the part normal?
Yes
Go to the next step.
No
Repair or replace the malfunctioning location and perform the repair completion verification.
Repair completion verification
VERIFY THAT VEHICLE IS REPAIRED
•  Install/connect the part removed/disconnected during the troubleshooting procedure.
•  Has the malfunction symptom been eliminated?
Yes
Complete the symptom troubleshooting. (Explain contents of repair to customer)
No
Refer to the controller area network (CAN) malfunction diagnosis flow to inspect for a CAN communication error.
If the CAN communication is normal, perform the diagnosis from Step 1.
•  If the malfunction is not resolved, replace the door-electrical supply unit (driver's side).