FUEL-FILLER LID LOCK ACTUATOR INSPECTION


id091400009600

1.  Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(E)].)

2.  Disconnect the fuel-filler lid lock actuator connector. (See FUEL-FILLER LID LOCK ACTUATOR REMOVAL/INSTALLATION [(E)].)

3.  Apply battery positive voltage and connect the ground to the fuel-filler lid lock actuator terminals as indicated in the table below and verify the operation condition.

am3zzw00029247

B+ terminal

Ground terminal

Operation

A
B
Unlock
B
A
Lock

•  If not as indicated in the table, replace the fuel-filler lid lock actuator. (See FUEL-FILLER LID LOCK ACTUATOR REMOVAL/INSTALLATION [(E)].)