NO MOTOR ASSIST
id140300000900
Troubleshooting item |
No motor assist |
---|---|
Description
|
• Energy flow display on center display does not work
|
Possible cause
|
• Environmental factor
• Related part malfunction (PCM inhibits motor assist as fail-safe)
|
System wiring diagram
|
• Not applicable
|
Connector diagram
|
• Not applicable
|
Diagnostic Procedure
Step |
Inspection |
Results |
Action |
---|---|---|---|
1
|
VERIFY DTCs
• Perform the DTC inspection.
(See DTC INSPECTION.)
• Is a DTC displayed?
|
Yes
|
Repair the malfunctioning part according to the applicable DTC troubleshooting.
|
No
|
Go to the next step.
|
||
2
|
VERIFY HOW CUSTOMER DRIVES VEHICLE
• Verify if any of the following conditions applies to how the customer drives the vehicle.
• Do any of the above conditions apply to how the customer drives the vehicle?
|
Yes
|
Explain to the customer that the vehicle is normal.
(No motor assist because motor assist operation conditions are not met.)
|
No
|
Go to the next step.
|
||
3
|
VERIFY M Hybrid BATTERY CONDITION
• Display the following PIDs using the M-MDS.
Mazda M Hybrid battery:
Integrated starter generator (ISG):
• Do any of the following PIDs apply?
|
Yes
|
HV_EV_BATT_SOC value is less than 50 %
• Start the engine and maintain engine idling until the HV_EV_BATT_SOC value is 50 % or more.
• Verify that the repairs have been completed.
BATT_TEMP_1 value is not within range of -20 °C {-4 °F}—60 °C {140 °F}
• Wait until the BATT_TEMP_1 is not within the range of the -20 °C {-4 °F}—60 °C {140 °F}.
• If the BATT_TEMP_1 value does not come within the range, verify if the floor undercover No.1 (RH) duct is clogged and repair the malfunctioning location if there is a malfunction.
• Verify that the repairs have been completed.
MOSFET_TEMP value is 100 °C {212 °F} or more
• Wait until the MOSFET_TEMP value is less than 100 °C {212 °F}.
• Verify that the repairs have been completed.
|
No
|
Go to the next step.
|
||
4
|
VERIFY INTEGRATED STARTER GENERATOR (ISG) TORQUE CONDITION
• Display the following PIDs using the M-MDS.
Integrated starter generator (ISG):
• Drive the vehicle.
• Is “-” displayed for either TRQ_REQ or TRQ_EST value?
|
Yes
|
“-” is displayed for TRQ_REQ value (requested torque from PCM not output)
• Replace the PCM
“+” is displayed for the TRQ_REQ value and “-” is displayed for the TRQ_EST value (requested torque from PCM output, but integrated starter generator (ISG) does not respond)
• Replace the integrated starter generator (ISG).
|
No
|
Go to the next step.
|
||
5
|
VERIFY CENTER DISPLAY INDICATION
• Display the following PIDs using the M-MDS.
Integrated starter generator (ISG):
• Drive the vehicle.
• When the PID TRQ_EST is 1.5 N·m {15 kgf·cm, 13 in·lbf} or more, is the energy flow displayed on the center display?
|
Yes
|
Explain to the customer that the vehicle is normal.
(Motor assist may be restricted for the purpose of system protection due to charge and temperature conditions of M Hybrid battery.)
|
No
|
Replace the center display.
|
||
Repair completion verification
|
VERIFY THAT VEHICLE IS REPAIRED
• Install/connect the part removed/disconnected during the troubleshooting procedure.
• Has the malfunction symptom been eliminated?
|
Yes
|
Complete the symptom troubleshooting.
(Explain contents of repair to customer.)
|
No
|
Refer to the CAN (controller area network) malfunction diagnosis flow to inspect for a CAN communication error.
If the CAN communication is normal, perform the diagnosis from Step 1.
• If the malfunction has not been resolved, replace the center display.
|