COOLING FAN MOTOR REMOVAL/INSTALLATION [ZY, Z6]
id0112a0801900
1. Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [ZY, Z6].)
2. Disconnect the negative battery cable.
3. Remove the aerodynamic under cover No.2. (See AERODYNAMIC UNDER COVER NO.2 REMOVAL/INSTALLATION.)
4. Remove in the order indicated in the table.
5. Install in the reverse order of removal.
am3zzw00006316
|
1
|
Connector
|
2
|
Wiring harness
|
3
|
Cooling fan component
|
4
|
Cooling fan No.1
|
5
|
Cooling fan No.2
|
6
|
Cooling fan motor No.1
|
7
|
Cooling fan motor No.2
|
8
|
Radiator cowling
|
Cooling Fan Component Removal Note
1. Remove the two installation bolts securing the fresh air duct to the shroud panel so that the fresh air duct is free to move. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION [ZY, Z6].)
2. Set the upper radiator hose and lower radiator hose out of the way with the hoses still connected. (ATX)
am3zzw00007876
|
3. Release the left and right tabs on the lower side of the radiator by pressing them in the direction shown in the figure.
am3zzw00006317
|
4. Lift the cooling fan component to remove it from the left and right insertion areas on the upper side of the radiator.
am3zzw00006318
|
5. Remove the cooling fan component from below the engine compartment.