MAIN RELAY CONTROL OPERATION [MZR 2.0 DISI i-stop]


id0140j1170200

•  When the ignition is switched to ON, the main relay turns on and power is supplied to sensors and devices.
•  When the ignition is switched to off, a main relay on command signal is received the main relay turns on and the following actions take place:
1.  Throttle valve control: Fully closed throttle learning function (See DRIVE-BY-WIRE CONTROL OPERATION [MZR 2.0 DISI i-stop].)
2.  After-cooling function of the electrical fan control (See ELECTRICAL FAN CONTROL OPERATION [MZR 2.0 DISI i-stop].)
•  When the on request signal from the controls stop, the main relay turns off.