DTC P2502[MTX, LF ATX (FS5A-EL)]
id0102b4814000
DTC P2502 |
Charging system voltage problem |
---|---|
DETECTION CONDITION
|
• The PCM judges generator output voltage is above 17 V or battery voltage is below 11 V during engine running.
Diagnostic support note
• This is a continuous monitor (Other).
• The MIL does not illuminate.
• FREEZE FRAME DATA is not available.
• The DTC is stored in the PCM memory.
|
POSSIBLE CAUSE
|
• Open circuit between generator terminal B and battery positive terminal
• Battery malfunction
• Generator malfunction
• PCM is poorly connected
• PCM, generator and/or battery are poorly connected
|
![]() |
Diagnostic procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
• Has FREEZE FRAME DATA been recorded?
|
Yes
|
Go to the next step.
|
No
|
Record the FREEZE FRAME DATA on the repair order, then go to the next step.
|
||
2
|
VERIFY RELATED SERVICE INFORMATION AVAILABILITY
• Verify related Service Information availability.
• Is any related Service Information available?
|
Yes
|
Perform repair or diagnosis according to the available Service Information.
• If the vehicle is not repaired, go to the next step.
|
No
|
Go to the next step.
|
||
3
|
INSPECT BATTERY
• Turn the ignition switch off.
• Inspect the battery.
• Is the battery normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the battery, then go to Step 7.
|
||
4
|
INSPECT POOR INSTALLATION OF GENERATOR TERMINAL
• Turn the ignition switch off.
• Inspect for looseness of generator terminal B installation nut.
• Is nut loose?
|
Yes
|
Tighten generator terminal B installation nut, then go to Step 7.
|
No
|
Go to the next step.
|
||
5
|
INSPECT POOR INSTALLATION OF BATTERY POSITIVE TERMINAL
• Inspect for looseness of battery positive terminal.
• Is the terminal loose?
|
Yes
|
Connect the battery positive terminal correctly, then go to Step 7.
|
No
|
Go to the next step.
|
||
6
|
INSPECT BATTERY CHARGING CIRCUIT
• Disconnect the generator terminal B.
• Measure the voltage between generator terminal B and body ground.
• Is the voltage B+?
|
Yes
|
Go to the next step.
|
No
|
Repair or replace the wiring harness between generator terminal B and battery positive terminal, then go to the next step.
|
||
7
|
VERIFY TROUBLESHOOTING OF DTC P2502 COMPLETED
• Make sure to reconnect all connectors.
• Clear the DTC from the PCM memory using the M-MDS.
• Start the engine, or KOER self‐test.
• Is the same DTC present?
|
Yes
|
Replace the PCM, then go to the next step.
|
No
|
Go to the next step.
|
||
8
|
VERIFY AFTER REPAIR PROCEDURE
• Perform “AFTER REPAIR PROCEDURE”.
• Is there any DTC present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
Troubleshooting completed.
|