VARIABLE SWIRL SHUTTER VALVE ACTUATOR INSPECTION[L3 Turbo]
id0113b5801200
1. Remove the air hose. (See INTAKE AIR SYSTEM REMOVAL/INSTALLATION[L3 Turbo].)
2. Disconnect the vacuum hose from the variable swirl control solenoid valve.
3. Connect a vacuum pump to the variable swirl shutter valve actuator.
4. Apply vacuum and verify that the rod moves.
Vacuum kPa {mmHg, inHg} |
Rod movement |
---|---|
–2.7 {–20, –0.7} or less
|
Not move
|
–33.4 {–251, –9.9} or more
|
Fully pulled
|