NEUTRAL SWITCH INSPECTION[LF, L3]


id0140a9800800


MTX

Note
•  Before performing the following inspection, make sure to follow the procedure as indicated in the troubleshooting flowchart.

Continuity Inspection

1.  Remove the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION[F35M-R].)

2.  Verify that the continuity between neutral switch terminals A and B is as indicated in the table.

am3zzw00001742

•  If it can be verified, perform the “Circuit Open/Short Inspection”.
•  If it cannot be verified, replace the neutral switch.

Measured condition

Continuity

Rod pushed
Continuity detected
Except above
No continuity


Circuit Open/Short Inspection

am3zzw00001743
acxuuw00000119

1.  Disconnect the PCM connector. (See PCM REMOVAL/INSTALLATION[LF, L3].)

2.  Inspect the following harness for open or short. (Continuity check)

Open circuit
•  Neutral switch terminal A and PCM terminal 1X
•  Neutral switch terminal B and body ground
Short circuit
•  Neutral switch terminal A and power supply
•  Neutral switch terminal B and body ground