DTC B1282, B1283
id070200800900
DTC B1282, B1283 |
Air mix actuator (potentiometer) system |
---|---|
POSSIBLE CAUSE
|
• Air mix actuator malfunction
• Open circuit in wiring harness between climate control unit and air mix actuator
• Short circuit in wiring harness between climate control unit (terminal N) and air mix actuator (terminal C)
|
Diagnostic Procedure
STEP |
INSPECTION |
ACTION |
|
---|---|---|---|
1
|
• Inspect the air mix actuator. (See AIR MIX ACTUATOR INSPECTION.)
• Is it normal?
|
Yes
|
Go to the next step.
|
No
|
Replace the air mix actuator. (See AIR MIX ACTUATOR REMOVAL/INSTALLATION.)
|
||
2
|
• Disconnect the climate control unit connector and the air mix actuator connector.
• Is there an open circuit in the wiring harness between the following terminals of the climate control unit and the air mix actuator?
|
Yes
|
Repair the wiring harness.
|
No
|
Go to the next step.
|
||
3
|
• Is there a short circuit to ground in the wiring harness between climate control unit terminal N and air mix actuator terminal C?
|
Yes
|
Repair the wiring harness.
|
No
|
The system is normal at present. (Clear the past malfunction from the memory.)
|
||
![]() |