DTC TABLE[IMMOBILIZER SYSTEM (ADVANCED KEYLESS SYSTEM)]
id0902e3800300
DTC |
Detection condition |
Page |
|||
---|---|---|---|---|---|
Security light flashing pattern |
M-MDS display |
||||
Keyless control module |
PCM |
||||
11
|
![]() |
B1681
|
P1260
|
No detected communication with the coil
|
|
12
|
![]() |
B2103
|
P1260
|
Coil malfunction
|
|
13
|
![]() |
B1600
|
P1260
|
The key ID number data cannot be read
|
|
B2431
|
P1260
|
Key ID number registration error
|
|||
14
|
![]() |
B1602
|
P1260
|
The keyless control module cannot read key ID number data normally
|
|
15
|
![]() |
B1601
|
P1260
|
The keyless control module has detected unregistered key ID number.
|
|
16
|
![]() |
U2510
|
P1260
|
Communication error between the keyless control module and the PCM (no response)
|
|
U1147
|
P1260
|
Communication error between the keyless control module and the PCM (mismatched conditions)
|
|||
21
|
![]() |
B1213
|
P1260
|
Only one key ID number is registered.
|
|
22
|
![]() |
B2141
|
P1260
|
Communication error between the keyless control module and the PCM (data transfer error)
|
|
23
|
![]() |
B2139
|
P1260
|
ID number data in the PCM and the keyless control module do not match.
|
|
Not illuminated
|
B1342
|
-
|
Keyless control module malfunction
|