KEYLESS CONTROL MODULE INSPECTION[KEYLESS ENTRY SYSTEM]


id0914008064b3

1.  Disconnect the keyless control module connector.

2.  Connect the negative battery cable.

3.  Attach the tester lead to the keyless control module wiring harness-side connector and inspect voltage, continuity, or resistance according to the standard (reference) on the table.


Standard (Reference)

am3zzw00002683

Terminal

Signal name

Connected to

Measured condition

Standard

Inspection item(s)

A
Power supply
PJB
Under any condition
B+
•  Related wiring harnesses
C
Data
PJB
Under any condition: Inspect the wiring harness between the keyless control module and PJB terminal J-04 F for continuity.
Continuity detected
•  transmitter
•  Related wiring harnesses
E
GND
Body ground
Under any condition: Inspect for continuity to ground.
Continuity detected
GND