PANEL LIGHT CONTROL SWITCH INSPECTION


id091800806400

1.  Measure the voltage at each terminal (other than terminal D).

•  If the voltage is not as specified in the Terminal Voltage Table (Reference), inspect the parts under “Inspection item(s)”.

2.  Disconnect the panel light control switch connector.

3.  Verify that continuity at terminal D is as indicated in the Terminal Voltage Table (Reference).

•  If there is any malfunction, inspect the parts under “Inspection item(s)”.
―  If the system does not work properly even though the parts or related wiring harnesses do not have any malfunction, replace the panel light control switch.


Terminal Voltage Table (Reference)

am3zzw00002536

Terminal

Signal name

Connected to

Measured condition

Voltage (V)/Continuity

Inspection item(s)

B
TNS
PJB
Turn the light switch to the TNS or ON position.
B+
•  ILLUMI 7.5 A fuse
•  Related wiring harnesses
Turn the light switch to the OFF position.
1.0 or less
D
GND
Body ground
Under any condition: Inspect for continuity to ground.
Continuity detected
•  GND
•  Related wiring harnesses
F
Panel light control
Illumination bulb
Panel light control switch turn to the brightest setting.
GND
•  Related wiring harnesses
Panel light control switch turn to the darkest setting.
H
Panel light control input
Panel light control switch
Panel light control switch turn to the brightest setting.
Approx. 4.5
•  Related wiring harnesses
Panel light control switch turn to the darkest setting.
1.0 or less


Terminals H Inspection

1.  Measure the wave pattern of panel light control switch terminals H using a tester.

am3zzw00002537

2.  Turn the light switch to the TNS or ON position.

3.  Verify that the resistance changes smoothly while turning the panel light control switch from the brightest to the darkest setting.